Filter Results By:

Products

Applications

Manufacturers

Showing results: 181 - 195 of 215 items found.

  • High Voltage Tester For Hair Dryer & Hair Straightner

    SCR ELEKTRONIKS

    Every electrical apparatus or machine consists of two distinct sections - one which carries the electricity, and other which is isolated (insulated) from the electric currents. The former may be called the `Live' side whiles the latter `Earth’ side. A person near about the apparatus or handling it can safely touch the Earth side, but not the live side, for obvious reasons. To ensure that the isolation of the two sections is effected properly, the apparatus is tested by subjecting it to a Voltage much higher than the normal working Voltage. If the insulation is good, it stands the test without breakdown otherwise high electrical stress punctures the insulation at its weakest spot foretelling a later calamity to unwary user. Government Department- when buying electrical equipments- and all reputable manufacturers test every piece of equipment by this test called HIGH VOLTAGE TEST. It weeds out poorly insulate apparatus.

  • Fully-Automatic Kjeldahl Analyzer

    LD-LKA-C10 - Labodam

    Fully-automatic Kjeldahl AnalyzerLD-LKA-C10conducts titration and distillation simultaneously so as to neutralize the ammonia gas released which enhance the test efficiency and avoid the overflow of ammonia. It stand with a measuring range from 0.1 to 200 mgN which gives a maximum recovery of ≥ 99.5 %. The operating ambient temperature of the device starts from 10 °C to 35 °C. 8.0-inch LCD touch screen is used to set the distillation time, the amount of diluent, acid liquor and alkali. Diaphragm pump is used to add reagent so that the injure caused by high pressure pump can be neglected. Wireless network modules is installed for realizing remote data transmission to test data processing and report printing.

  • Torque Gauges

    Mark-10 Corp.

    Mark-10 torque gauges and torque testers are accurate and feature-rich torque measurement products ideal for a wide range of torque applications. All torque gauges and torque testers capture the peak torque in both directions (CW and CCW) and have selectable units of torque measurement. Torque capacities are available from 10 ozFin full scale to 5,000 lbFin, depending on the torque gauge or torque tester. Units may be handheld or used with a test stand and gripping fixtures to create a complete torque testing solution. All torque gauges and torque testers carry the CE mark.

  • 8 Function Professional MultiMeter - Averaging, Manual Ranging DMM with Large Backlit LCD Display and Temperature Function

    Extech EX410A - Extech Instruments Corporation

    Compact and powerful, the Extech EX410A Eight-Function True RMS Professional MultiMeter provides the versatility of multiple meters in one convenient device. The EX410A measures AC/DC voltage and current, resistance, diode, and temperance. A large, backlit display and 1-inch high digits allow for easy reading, while the ergonomically designed housing offers comfortable, one-handed operation. Comes with Multimeter, CAT III test leads, stand, hanging strap, holster with built-in test lead storage, Type K bead wire temperature probe, and battery.

  • Peel Testers

    IMADA, Incorporated

    Imada offers motorized peel testers in vertical or horizontal configurations.The motorized test stand, digital force gauge and peel fixture apply tension to a safety seals, tapes and laminates.Special attachments and fixtures facilitate 45°, 90°, 180°, ‘T’ and rotary peel tests.Motorized peel testers offer speed control and highest degree of repeatability with the ability to set a constant test speed and range of movement.All peel testers with digital force gauges have data output capability for analysis by optional data acquisition software.

  • Industrial Pressure Calibrator

    2271A - Fluke Calibration

    The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and budgets, and expanded to cover a broad workload. The 2271A is ideal for calibration laboratories starting out in pressure calibration because it offers wide pressure measurement capabilities in a single instrument. Everything you need for calibrating pressure is included; just connect supply pressure. And your investment will stand the test of time: as your workload grows and changes, the 2271A can grow and change too. Just add measurement modules.

  • CD/DVD Analyzer

    Shuttleplex - Mediatechnics Systems Inc.

    The ShuttlePlex CDVD Analyzer can be configured to automatically test, save, report, grade, print and export your optical disc data. The unit is designed to provide an efficient, effective, low cost analysis for just about any optical disc production process. The User interface provides a feature set and graphical environment (See Below) similar to those used by Professional Engineers in a Disc Manufacturing Environment. The Unit was designed with Duplicators, Web Disc, Game Designers, Media Distributors and Archivalists in mind. The ShuttlePlex can be purchased in Several configurations; as a stand alone unit, external laptop drive or integrated into a PC based duplication system.

  • Probecard testers

    MANAGER - Beijert Engineering BV

    Today more complex probe cards are being used. More pins,higher density and larger array requires a new approach inprobe card analysis. With the soaring cost of new generationprobe cards, repair of defective cards becomes an necessity.BE Precision Technology offers all capabilities with the newMANAGER V. Future proof, up to 450 mm full wafer contactprobe cards can be analyzed with up to 88.000 test channels.High-end materials are used to stand extra tough requirements—such as 500 mm diameter diamante viewing window,ultra stiff carbon flip-table, high power Z–stage to generate 600Kg of contact force

  • Engine Test Adapters

    Atec, Inc.

    Atec has built test adapters for a wide variety of engines from high bypass fan engines to small APU engines. Testing a new engine type in your existing jet engine test cell can be challenging, and upgrade modifications will be needed. Atec does not view an adapter as just a mechanical weldment that simply mates the engine to the aeroengine thrust stand. Our engineers realize that additional items will be needed in the facility to insure total project success. During the planning phase, Atec engineers can visit your existing facility and/or review videos to make a comprehensive assessment of the integration needed to add a new engine type to your testing facility. Atec can perform airflow, acoustics, FEA and sub systems analyses to ensure that any new engine added to your jet engine test cell will have the proper capacity to perform properly. Vital Link’s current experience with advanced fighter engines test adapter kits further bolsters our expertise in high thrust engine test handling.

  • Multimedia Test Systems

    Alfamation S.p.A

    Consumers demand innovative electronic devices with advanced features, and manufacturers need to deliver products that stand out from a growing field of competitors. At the same time, they are challenged to get their products to market quickly, at a lower cost, while operating in a complex global environment. Alfamation's turnkey solution can automatically run a wide range of tests, including power up, video (RF, CVBS, S-Video, HDMI), audio (analog, digital, HDMI), remote controls.

  • 8/16-CH 16-Bit 250 kS/s Multi-Function USB DAQ Modules (OEM Version Available)

    USB-1901/1902/1903 - ADLINK Technology Inc.

    The ADLINK USB-1900 series provides a range of USB 2.0-based multi-functional DAQ modules. The USB-1901 and USB-1902 16-bit 250 kS/s USB 2.0-based high-performance DAQ modules allow four different voltage input ranges, while the USB-1903 features additional built-in precision current-tovoltage resistors capable of direct measurement of current signal from 0 to 20 mA. The USB-1900 series is USB bus powered and equipped with removable screw-down terminals for easy device connectivity. The attached multi-functional stand can be used for desktop, rail, or wall mounting. Suitable for mixed-signal tests, laboratory research, and factory automation, the USB-1900 series provide a simple measurement solution at an affordable price.

  • 8 Function True RMS Professional MultiMeter

    Extech EX411A - Extech Instruments Corporation

    The EX411A offers multiple functions so you can carry one meter into the field instead of several. The manual-ranging EX411A measures AC/DC voltage, AC/DC current, resistance, diode, and continuity, all with +/-0.5 percent basic accuracy. The unit has low current capability, measuring down to 0.1uA, and features input fuse protection and mis-connection warnings. A Type K thermometer is built in for surface or air temperature measurements. Comes with CAT III test leads, stand, hanging strap, holster with built-in test lead storage, Type K bead wire temperature probe, and battery.

  • Dial Indicators

    Rhopoint Metrology Ltd

    1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.

  • Test Solutions For OEMs

    Testek Solutions

    A partnership with Testek Solutions fits into your business because we do business like youdo business. Our partnerships are built on open communication, process transparency, and trust – trust that is built on our proven engineering design process. We assign a dedicated team consisting of a program manager who will be your single-point-of-contact, an experienced project engineer to design and oversee all engineering on the project, and any supporting engineers and manufacturing team members necessary for every project. Each test stand goes through a series of stage gates including an initial review of requirements, preliminary design review, critical design review, final design and manufacturing review, and a quality review regardless of whether you request these reviews.

  • ExStik® 3-in-1 Chlorine, pH, Temperature Kit

    Extech EX800 - Extech Instruments Corporation

    The Extech EX800 ExStik 3-In-1 Kit includes the CL200 meter and pH electrode, reagent tablets (50 tests), four plastic cups, a weighted stand, pH buffer pouches, four CR2032 batteries, 48 inch neck strap, carrying case, and user manual. The meter measures Total Chlorine, pH, and Temperature with interchangeable flat surface electrodes that are included. Flat surface electrodes work in liquids, semi-solids and solids. Built-in memory can store/recall up to 15 readings and save the last calibrated value. It has a large 3-1/2 digit (2000 count) digital display with a bargraph and an automatic electronic self-calibration function for Chlorine (1, 2, or 3 point buffer calibration for pH).

Get Help